BAM-7 Pro Vet
Single tank anesthesia machine
The BAM-7 Pro is an advanced, multifunctional, and cost-effective anesthesia device with a sleek and compact design that incorporates concealedpipelines. This innovative design minimizes the potential impact of leakage,wear, and twisting of exposed pipelines during operation, thereby enhanc-ing the overall reliability of the product. Equipped with cutting-edge technology, the BAM-7 Pro boasts features such as an APL valve, ACGO switch,AGSS, an accurate flow meter, a wide range of ventilation modes, andhigh-performance vaporizers that offer various anesthesia agents and fillingmethods. As a result, the BAM-7 Pro is extensively utilized in a variety ofsettings, including pet hospitals, university laboratories, and animal clinics.
Feature
Machine mounting system
Mobile trolly; wall mount; pendant mount.
Special veterinary Ca(OH)2 canister
Greatly reducing the possibility of circuit and mechanical dead space, and increasing the security of anesthesia in operations.
Standard configuration
Breathing pipe and Y-piece connector, anesthesia mask,inhalation/exhalation check valve kit, CO2 absorber module.bracket, breathing system, breathing bag.
Oxygen Pressure Security
Oxygen pressure gauge, oxygen pressure status is clear;built-insafety valve ensures product safety.
Large CapacityCO2AbsorberCanister
Lever mechanism, locking and unlocking by only one-step;1400ml super large capacity CO2 absorber canister.
Airway Pressure Management
Pre-calibrated APL valve, set airway pressure level in one step; APLvalve button closes the airway by one-step;vertical pressure airway gauge, airway pressure status is under control.
Independent non-rebreathing Circuit
All-metal ACGO switch and independent ACGO port to ensure one-step switching between rebreathing anaesthesia and non-rebreathing anaesthesia.
Technical Specification
Dimensions | 500x500X1310mm |
---|---|
Weight | 50kg |
Materials | All materials in contact with exhaled patient gases are autoclavable up to a maximum temperature of 134℃,except mechanical pressure gauge.
All materials in contact with patient gas are latex free. |
Gas supply | 0.28~0.6MPa |
Flowmeter | O2 , 0~4L/min |
Oxygen flush | 25L/min~75L/min |
Anesthesia rebreathing circuit
CO2 absorber Adjustment range of APL |
Ca(OH)2 canister 500ml, 0~50cmH2O |
Vaporizer with flow, pressure and temperature compensation,
Vaporizer Vaporizer mounting system |
lsoflurane 0~6VOL% Sevofflurane0~8VOL% Enfflurane0~8VOL%Selectatec®, interlock |
Breathing bag | 3L,2L,1L,0.5L |
Breathing system cornectors
Exhalation 22mm. lnhalation 22mm Manual bag port 22mm |
OD/15mm ID conial
OD/15mm lD conial OD/15mm ID conial |
Airway pressure gauge | -20~100 cmH2O |
AGSS | Anaesthetic gas scavenging system |
Operating environment
Temperature Humidity (non-condensing) Atmosphere pressure |
10~40℃
15%~95% 70~106Kpa |
Transportation environment Termperature Humidity(non-condensing) Atmosphere pressure |
-20~55℃ 10%~95% 50~106Kpa |